Keywords:  *
JQ-37F Contactor using in the hard environmental condition seriesTotal > RELAYS > Special Relay > JQ-37F Contactor using in the hard environmental condition series
JQ-37F Contactor using in the hard environmental condition series
JQ-37F Contactor using in the hard environmental condition
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
Brief introductionJQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition seriestop ↑
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
JQ-37F Contactor using in the hard environmental condition
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
specificationJQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition seriestop ↑
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
Coil power (W)
≤7
Load Range of Contact Resistance
5~150A,
5~380Va.c.
Contact Resistance (mΩ)
Initial Value
≤50
After Life Testing
≤150
Insulation
Resistance
(MΩ)
Normal
≥1000
Maximum Switching Power
57000VA
High Level Life
≥100
Contact Load and Life
150A,380Va.c.,50Hz,3Φ, 10,000 operations
Dielectric Strength
Vr.m.s.
(50Hz)
Normal Pressure
1800
Low Pressure
400
Weight(g)
≤1300
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
how to orderJQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition seriestop ↑
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
JQ-37F  /  024  -  1
(1)     (2)     (3)
(1) Model No.
(2) Specification NO.
(3)Installation Type No.
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
Environmental ConditionJQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition seriestop ↑
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
Ambient Temperature Range (℃)
-55~85℃
Relative Humidity
98%(at 40℃)
Low Pressure (kPa)
2.5
Vibration
98m/s2 , 10-500Hz
Shock Resistance(m/s2)
196
Acceleration(m/s2)
245
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
Main Technical DataJQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition seriestop ↑
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
No.
Coil voltage
25℃
Temperature range
Rated
Max
Coil Resistance
(Ω)±10%
Working Voltage
(Max)
Sustaining Voltage
(Max)
Release Voltage
(Min)
Working Voltage
(Max)
Sustaining Voltage
(Max)
Release Voltage
(Min)
Holding
Startup
024
24
26.4
82.0
6.0
15.1
7.2
1.7
20.0
12.0
1.0
027
27
29.7
103.5
7.5
18.0
8.1
1.9
23.0
13.5
1.1
036
36
39.6
185.0
13.0
24.0
10.8
2.5
30.6
18.0
1.5
060
60
66.0
510.0
36.0
40.0
18.0
4.2
51.0
30.0
2.5
110
110
121.0
1725.0
125.0
73.3
33.0
7.7
93.5
55.0
4.6
220
220
242.0
6920.0
500.0
154.0
74.0
22.9
182.6
110.0
13.8
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series